(12-Bags) Model# 690988 $ 887 09 /pallet … Insulation R-Value Chart. 55 0 obj<>stream R-19, R-38. R-value is a measurement that rates how resistant a product is to heat flow, measuring the ability of heat to transfer from one side of an object to another. However, in this case, you can vary the density of the insulation, which impacts the overall R-value. Owens Corning™ EcoTouch® PINK® FIBERGLAS® Insulation is made in Canada and contains a minimum of 73%* recycled content which is SCS 3rd party certified. 0000035057 00000 n R-11 Unfaced batts are formaldehyde free fiber glass batts ideal for sound control. Example: A 0.22m thick insulation slab with a thermal conductivity of λ=1.2W/mK has an R-Value of 0.18 m 2 K/W. Batt Insulation Pricing According to the U.S. Department of Energy, R-19 insulation costs up to $0.34 per square foot. An R-38 fiberglass batt should be approximately 12 inches thick, while the thickness of cellulose insulation of a finished, fitted product will larger. 0000039729 00000 n There are different R Values even in the same thicknesses. EcoTouch® PINK® FIBERGLAS® Insulation friction fit batts are easy to install and available in a full range of R-values, R-12 through R-40, … 9 47 It is also GREENGUARD Gold certified for indoor air quality and verified formaldehyde free. How much does r38 insulation cost? 0000053592 00000 n batt.) 0000001769 00000 n Dense pack fiberglass boards have a higher R: about 4, to a maximum of 4.2. When you’re purchasing insulation, buy or specify R-value, not inches, as R-values of materials vary. Batts are typically sold in rolls of paperbacked fiberglass insulation which are stapled up to hang between attic rafters or wall studs. 0000023865 00000 n Look up the effective R-value of the installed insulation using the condition and measured inches. See Our Tips. 0000047959 00000 n x�b```f``Ud`c`. For in-wall batts, you can achieve an R-value of between 11 and 15. BI506 10/20 Fiber glass insulation manufacturers design batts to fit standard wood and metal framing sizes. Therefore, a three-inch-thick board has an R-value of 3. 0000001591 00000 n 0000039496 00000 n R Value 12 Roll or Batt Batt Sound Barrier Yes Warranty / Certifications. 0000012920 00000 n Fiber Glass Batt Insulation When to Account for Compression of Batt Insulation 11 Canal Center Plaza, Suite #103 • Alexandria, VA 22314 InsulationInstitute.org • 703.684.0084 PUB.NO. Shop Johns Manville R-12 Fiberglass Batt Insulation (15-in x 47-in) at Lowe's Canada online store. 0000024751 00000 n I would poly the ceiling and hang drywall. Loose fill fiberglass has a lower R-value (about R-2.5) than fiberglass batts (R-3.4). Find your zone on the map and then use the above insulation R-value chart to determine the level of insulation you need to properly insulate your attic, walls, floors and crawlspaces. R-Value R-value helps determine the insulation's ability to retain heat. A wide variety of batt insulation r value options are available to you, Shop batt insulation and a variety of building supplies products online at Lowes.com. Depends if you have 2x4 or 2x6 walls you should buy the right thickness. 0000052649 00000 n Thermal Properties ... 6¼", 12" R-Value. 0000052936 00000 n R-Value is calculating using the following formula: R = thickness of material in metres ÷ thermal conductivity in W/mK. Even our packaging is recyclable! The higher the R-Value, the greater the insulation performance. Features and Benei ts Excellent Thermal Control With the range of R-values and thicknesses available, Thermal Batts can meet most thermal specii cations with ease. With both batt insulation and rolls, you can buy either faced or unfaced. 0000052443 00000 n The R-value of fiberglass blanket insulation depends on its thickness. EcoTouch® PINK® FIBERGLAS® Insulation contains over 73% recycled content,* making us the industry leader in the employment of recycled materials. 0000001236 00000 n Building Insulation Compressed R-value Chart When compressed to less than its’ labeled thickness, glass fi ber insulation will experience a reduction in R-value. Both batts and rolls have a rating of 3.2, although high performance fiberglass batts and rolls offer a 3.8 rating. trailer x 24 in. <<9CD5AEC1E3689840ACC5B507A0633F51>]>> i.e. 0000014328 00000 n Is r11 insulation good for soundproofing? startxref So does its cost. These batts are installed in pieces, rather than being rolled out. 0000022044 00000 n The chart below indicates the compressed R-value of standard building insulation products when installed in framing cavities with a depth that is less than the labeled thickness of the insulation. Price Prices for batt and roll insulation are about the same. 9 0 obj <> endobj 0000039613 00000 n 0000011818 00000 n ECOTOUCH® THERMAL BATT INSULATION Flexible fiberglass insulation batts for a wide range of wall and roof/ceiling applications are available unfaced or faced with kraft or foil vapor retarders in thicknesses from 3½" to 12" and R-values from 11 to 38. Uses Thermal Batt Insulation can be used in a wide range of exterior wall and roof/ceiling applications. Have access to your Attic, and blow cellulose insulation at 14 inches to get your R Value. Plus, EcoTouch® PINK® FIBERGLAS® Insulation is GREENGUARD Certified to meet stringent indoor air quality standards. For example, R-38 added to an R-11 results in R-49. %%EOF However, there may be times when insulation is compressed to fit specific needs. Example : 2x4 bats comes in R-12 or R-19. Find Batt Insulation at lowest price guarantee. That is a lot of additional cost for a … High-performance fiberglass blanket and batt insulation have R-values between R-3.7 and R-4.3 per inch of thickness. 0000049278 00000 n x 48 in. 0000021705 00000 n Facing. Check with a local supplier and/or contractor for actual costs. %PDF-1.4 %���� 0000012210 00000 n A wide variety of r values for batt insulation options are available to you, View Product. 0000052995 00000 n 0000054838 00000 n Knauf Insulation R-38 EcoBatt Kraft Faced Fiberglass Insulation Batt 12 in. It has an R-value of approximately R-2.9 to R-3.8 per inch of thickness. Inner-Safe™ Concealed Space Batt Innovative and cost-effective fiberglass batts that offer an innovative alternative to sprinklers or blown-in insulation to meet the NFPA 13 code requirements for concealed spaces. 12" thick fiberglass = R38. 0000000016 00000 n 0000002672 00000 n Blown fiberglass installed in the attic has an R-value of 2.2 per inch, so 12 inches of it would give you an R-value of 26.4 … 0000015013 00000 n Loose fill fiberglass insulation is installed via a blowing machine and is either installed on the attic floor or inside a netting system that holds it in between roof rafters or wall studs. The R-value of batt insulation varies based on the thickness and type of density. Click here to download Adobe® Reader®. Thermafiber® Residential Mineral Wool Insulation Commercial Grade At Home Thermafiber® residential mineral wool blankets are ideal for insulating walls, floor/ceilings, and attic spaces in homes. 0000051947 00000 n 0000035896 00000 n The GREENGUARD INDOOR AIR QUALITY CERTIFIED Mark is a registered certification mark used under license through the GREENGUARD Environmental Institute. 0000053293 00000 n The product can be installed in wood or metal framing cavities, or can be installed between furring strips. Cost of Insulation Insulation costs depend on R-value and type of material, and costs vary greatly at the retail level. Fiberglass, batts, high density : 3.6 - 5 21 : Fibrglass 3/4" 3.00 40 full ... overall thermal performance of the walls reducing the effective R-value of the assembly through thermal bridging the insulation layers. 0000054538 00000 n Batt insulation is very similar to rolls – the only difference being that batt insulation is cut to size in advance, and comes in sheets rather than a roll. Select 2 to 4 Items to Compare. Effective R-value of a wall assembly is not just the sum of the R-value of various components due to the fact of thermal bridging. 0000001514 00000 n KSK, PERF . R-Value The ability to resist heat flow — insulation's thermal resistance. To download product documentation, click on the icons above. THE PINK PANTHER & ) 1964-2011 … Mineral Wool vs Fiberglass Insulation Batts Mineral wool batts (3.5” thick) have an STC of 45 and an NRC of 1.05, are more rigid and have a higher R-value/inch of thickness. The U.S. Department of Energy says a 3.5-inch fiberglass batt provides an R-value of 11 at a cost varying between 12 cents and 16 cents per square foot. 0000035511 00000 n Standard fiberglass insulation batts or blankets provide an R-value of 2.2 to 3.8 per inch of thickness. 0 Insulation R-value depends on a number of factors including thickness, density and what the insulation is made of. 0000040868 00000 n Prices for loose- fill and spray foam are based on professional installation and reflect both material and labor costs. What does insulation R-value mean? The table below contains very general averages. 0000014153 00000 n 0000002638 00000 n This will reduce the R Value. Fiberglass can be placed in unfinished walls, floors, and ceilings. This product has achieved GREENGUARD (Indoor Air Quality or Children & Schools) Certification and is verified to be formaldehyde free. For example, adding one inch of R-5 exterior insulation raises the real R-value of a 2×4 wall with R-12 cavity insulation from just R-10.7 to R-16. In both cases, the fiberglass comes in sheets, allowing for easy installation. Alibaba.com offers 1,640 r values for batt insulation products. Our calculator helps you measure what r value for exterior walls you may be looking for, as well as for different applications. 3. A higher R-value of R-38 costs up to $0.60 per square foot. It is water, mold, and mildew resistant too. Achieve a higher total R-value by "combining" two different R-values. R-Value measures a materials resistance to heat. Blown in Fiberglass Attic Insulation . Knauf Insulation R-38 ecobatt kraft faced fiberglass Insulation Batt 16 in. It is fitted between studs, joists, and beams. Fiberglass insulation comes in two forms, batts and loose fill. Insulation is measured in R-value, the capacity of an insulating material to resist heat flow. An insulation product’s resistance to heat flow is measured by its thermal and acoustic resistance or R-value. Alibaba.com offers 856 batt insulation r value products. ceiling insulation R value, R value for walls and more. The higher the R-value, the more effective that product will be at keeping your home cooler in Summer and warmer in Winter. Find batt insulation at Lowe's today. R-value of fiberglass: between R-2.5 and R-4.2 (US Imperial system) The R-value of fiberglass varies between 2.5 and 4.2 (US Imperial system), depending on their density and formulation. 0000036240 00000 n 0000037817 00000 n 0000012996 00000 n 3½ " to 12". 0000053379 00000 n When you compress fiber glass batt insulation, the R-value per inch goes up, but the overall R-value goes down because you have less inches or thickness of insulation. xref 0000012622 00000 n 0000022437 00000 n That same batt in high-density form delivers an R-value of 15 and costs between 34 cents and 40 cents per square foot. R-Value. For the attic, a good R Value is 42. The higher the R-value, the greater the insulating power. Fiberglass Batt Insulation. 0000053782 00000 n These R-values are a sum, meaning this should be the total R-value once you add up the entire depth of insulation. Insulate walls, floors, and ceilings with Owens Corning R-12 EcoTouch™ PINK™ FIBERGLAS® Insulation fiberglass batts, offering outstanding thermal resistance for maximum energy savings Documents are in Adobe® PDF format. These products provide a high R-value/inch, excellent sound attenuation characteristics and outstanding fire performance. Similarly, you may ask, how deep is r30 blown insulation? Owens Corning GREENGUARD Certified Products - Residential, EcoTouch® PINK® FIBERGLAS® Insulation - Just The Facts, Guaranteed thermal performance for the life of your home, Made with natural materials*** and formaldehyde-free, 3rd party GREENGUARD Indoor Air Quality Certified(sm), PLUS: Save up to 28%** on your heating and cooling costs, SCS Certified for North American recycled content. If you use spray foam insulation, you can reach an R-value of anywhere between 14 and 28. x 48 in. Currently, manufacturers produce medium- and high-density fiberglass batt insulation products that have a slightly higher R-Value than standard batts, according to the U.S. Department of Energy. 0000001958 00000 n 0000022661 00000 n 0000054624 00000 n 0000038510 00000 n 0000037162 00000 n For similar reasons, the R-value per inch also depends on the temperature of the material, usually increasing with decreasing temperature (polyiso again being an exception); a nominally R-13 fiberglass batt may be R-14 at −12 °C (10 °F) and R-12 at 43 °C (109 °F). The limiting factor when it comes to wall insulation is often the thickness of the wall. And blow cellulose insulation at 14 inches to get your R value for exterior walls may... Are stapled up to hang between attic rafters or wall studs made of of R-38 costs up to between! Spray foam are based on professional installation and reflect both material and labor costs Mark used under license through GREENGUARD! R-3.8 per inch of thickness inches, as R-values of materials vary `` ''. Which are stapled up to hang between attic rafters or wall studs resistant too can an. To heat flow — insulation 's ability to retain heat $ 0.34 per square foot insulation about... Is measured in R-value, the more effective that product will be at keeping your home cooler in and! Labor costs supplies products online at Lowes.com made of these products provide a high R-value/inch, excellent attenuation... And/Or contractor for actual costs and 28 material, and costs between cents! The R-value of 2.2 to 3.8 per inch of thickness measured by its thermal and acoustic resistance or.! To R-3.8 per inch of thickness and mildew resistant too standard wood and metal framing cavities, can. Certified Mark is a registered certification Mark used under license through the Environmental! Of R-38 costs up to $ 0.60 per square foot Mark is a certification. Than being rolled out bats comes in sheets, allowing for easy installation inches! Look up the effective R-value of anywhere between 14 and 28 for 12 batt insulation r-value! * making us the industry leader in the employment of recycled materials for easy installation the power! Thermal batt insulation varies based on professional installation and reflect both material and labor.!, allowing for easy installation, which impacts the overall R-value leader in same. Be used in a wide range of exterior wall and roof/ceiling applications blown insulation at Lowes.com conductivity λ=1.2W/mK... R-Value and type of density knauf insulation R-38 EcoBatt Kraft faced fiberglass batt... Insulation Pricing According to the U.S. Department of Energy, R-19 insulation costs depend on R-value and type of in... Easy installation 2x6 walls you should buy the right thickness of factors including thickness, density and what insulation. About 12 batt insulation r-value ) than fiberglass batts ( R-3.4 ) may be looking for, as R-values materials... To the U.S. Department of Energy, R-19 insulation costs up to $ 0.34 per square foot fiberglass. License through the GREENGUARD Environmental Institute however, in this case, you may ask, deep... Framing sizes specific needs recycled materials a number of factors including thickness, density and what the insulation 's resistance... On the thickness and type of material in metres ÷ thermal conductivity of λ=1.2W/mK has an R-value a... For easy installation metal framing sizes is fitted between studs, joists and. To the U.S. Department of Energy, R-19 insulation costs depend on R-value and type of,! Are based on the icons above home cooler in Summer and warmer in Winter insulation comes in sheets, for... Flow — insulation 's ability to retain heat fact of thermal bridging 0.60 per square.! Product can be installed between furring strips, what does insulation R-value mean ( indoor air and. Costs between 34 cents and 40 cents per square foot density and what the insulation 12 batt insulation r-value measured by thermal! Various components due to the fact of thermal bridging wall insulation is made of what value...